VALVES & ACCESSORIES
OS&Y Gate Valve (Flanged, Grooved etc)
Certificate: UL Listed/ FM Approved
Standard: BS 5163
UL 262/ AWWA C515
Connection: Flanged as BS EN 1092-2 + Grooved as ISO 6182/ Flanged as ASME B16.1 + Grooved as AWWA C606
Temperature: 0°C to 100°C
W. pressure: PN 16/ 300 psi (2.07 Mpa)
Surface: FBE coating as AWWA C550
Download PDF
Supervisory/ Tamper Switch
Certificate: UL Listed/ FM Approved/ CE
Cover: Die-casting aluminium as ASTM B85
Connection plate: Mild steel/ SS
Trip rod: SS304/ SS316
Temperature: -40°C to 60°C
Surface: Corrosion resistant coating
Enclosure: IP 65 and IP 67
Download PDF
Swing Check /Non-Return Valve
Certificate: UL Listed/ FM Approved
Standard: EN 1074-3
UL 312/ AWWA C508
Connection: Flanged as BS EN 1092-2/ Flanged as ASME B16.1
Temperature: 0°C to 100°C
W. pressure: PN 16/ 300 psi (2.07 Mpa )
Surface: FBE coating as AWWA C550
Download PDF
Butterfly valve with Supervisory Option
Certificate: UL Listed/ FM Approved
Standard: EN 593/ BS 5155
UL 1091/ MSS SP-67
Top flanged: ISO 5211
Indicator: Flag type position indicator
Temperature: 0°C to 100°C
W. pressure: PN 16/ 300 psi (2.07 MPa)
Surface: FBE coating as AWWA C550
Download PDF
Alarm Check Valve Assembly
Certificate: UL Listed/ FM Approved
Standard: ANSI/ UL 193
Connection: Flanged as ANSI B16.1/ EN 1092-2
Installation: Vertical
Test: Factory hydro test 350 psi (2.4 MPa)
Temperature: 4°C to 70°C
W. pressure: 175/ 300 psi (1.21/ 2.07 MPa)
Surface: FBE coating as AWWA C550
Download PDF
Pressure Switch
Certificate: UL Listed/ FM Approved
Standard: UL 753/ FM3132
Size: 130 x 84 x 108mm
Connection: 1/2″ NPT male
Temperature: -40°C to 71°C
Enclosure: Rated UL 4X/ NEMA 4 (IP54)
Download PDF
Deluge valve
Certificate: UL Listed
Standard: ANSI/ UL 193
Connection: Flanged as ANSI B16.1/ EN 1092-2
Installation: Horizontal/ Vertical
Test: Factory hydro test 350 psi (2.4 MPa)
Temperature: 0°C to 68°C
W. pressure: 300 psi (2.07 MPa)
Surface: FBE coating as AWWA C550
Download PDF
Y Strainer
Certificate: UL Listed
Standard: UL Subject 321
Screen: Standard perforation
Seat: Recessed seat for screen alignment
Connection: Flanged as EN 1092-2/ Flanged as ANSI B16.1
Temperature: 0°C to 100°C
W. pressure: PN 16/ 300 psi (2.07 Mpa)
Surface: FBE coating as AWWA C550
Download PDF
Fire Pump Flowmeter
Certificate: FM/ LPCB Approved
Size: 2″ to 8″
Connection: Wafer flange/ grooved
Scale: Both US gpm and dm
3
/ min
Accuracy: ±2%
Installation: Horizontal/ vertical
W. pressure: 290 psi (2.0 MPa)
Download PDF
Air release valve
Certificate: UL Listed/ FM Approved
Standard: UL Subject 2573
Connection: NPT/ BSPT
Temperature: 0°C to 90°C
Surface: FBE coating as AWWA C550
Download PDF
Brass Ball Valve
Certificate: UL Listed
Standard: MSS SP-110, NSF/ ANSI 61
Connection: Female thread, NPT/ BSPT
Hydro test: Shell 900 psi/ Seat 660 psi
Air test: Min 80 psi
Temperature: -30°C to 120°C
W. pressure: Class 150: WOG 600 psi & SWP 150 psi
Surface: Rough brass
Download PDF
Test and drain valve
Certificate: UL Listed/ FM Approved
Standard: UL Subject 258
Connection: Female thread, NPT or BSPT/ grooved
Hydro test: 350 psi
Temperature: 0°C to 100°C
W. pressure: 175 psi
Surface: Rough brass
Download PDF
Waterflow indicator
Certificate: UL Listed/ FM Approved
Standard: ANSI/ UL 346
Sensitivity:Flow rate 4-10 US GPM
Contact ratings: 8A at 125/250 VAC, 3A at 24VDC, 2.5A at 30VDC
Maximum surge: 18 feet per second (FPS)
Temperature: 0°C to 68°C
W. pressure: 450 psi
Surface: FBE coating as AWWA C550
Ref. No.: V38
Download PDF
Pressure gauge
Certificate: UL Listed/ FM Approved
Standard: UL 393/ ASME B40.100
Dial diameter: 3.5″ (90mm)
Connection: 1/4″ NPT
Full scale value: 300 psi
W. pressure: Max 75% of full scale value
Accuracy: 3% – 2% – 3% as ASME Gr. B
Temperature: -40°C to 65°C
Enclosure: IP 52
Download PDF
Pressure Reducing Valve
Certificate: UL Listed/ FM Approved
Standard: ANSI/ UL 1468
Connection: Flanged as ANSI B16.42
Pres. adjustment: 30 ~ 165 psi.
Pres. differential: Min 10 psi
Temperature: Water, max 82°C
W. pressure: Class 150/ class 300
Surface: FBE coating as AWWA C550
Download PDF
Foot valve
Certificate: ISO
Connection: Flanged as ANSI B16.5/ EN 1092-2
Test: 348/ 544 psi (2.4/ 3.75 Mpa)
Temperature: EPDM, -20°C to 110°C/ NBR, -10°C to 80°C
Surface: Green/ blue painting
Model: U14
Download PDF
Waste cone
Certificate: ISO/BS
Standard: NFPA 20
Connection: Flanged as ANSI B16.5/ EN 1092-2
Body: Single body casting as DI
Sight glass: 2 x SS316
Surface: FBE coating as AWWA C550
Download PDF
Anti-Vortex Plate
Certificate: ISO
Standard: EN 12845
Connection: Flanged as ANSI B16.5/ EN 1092-2
Material: SS304
Temperature: 0°C to 120°C
Surface: Rough SS/ red painting
Download PDF